hkr.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Psychometric performance of a generic walking scale (Walk-12G) in multiple sclerosis and Parkinson's disease
Department of Health Sciences, Lund University, Lund, Sweden.
Department of Health Sciences, Lund University, Lund, Sweden.
Department of Community Medicine and Rehabilitation, Umeå University, Umeå, Sweden.
Högskolan Kristianstad, Sektionen för hälsa och samhälle, Avdelningen för Hälsovetenskap. Högskolan Kristianstad, Forskningsmiljön PRO-CARE.ORCID-id: 0000-0003-4820-6203
Vise andre og tillknytning
2012 (engelsk)Inngår i: Journal of Neurology, ISSN 0340-5354, E-ISSN 1432-1459, Vol. 259, nr 4, s. 729-738Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Walking difficulties are common in neurological and other disorders, as well as among the elderly. There is a need for reliable and valid instruments for measuring walking difficulties in everyday life since existing gait tests are clinician rated and focus on situation specific capacity. The Walk-12G was adapted from the 12-item multiple sclerosis walking scale as a generic patient-reported rating scale for walking difficulties in everyday life. The aim of this study is to examine the psychometric properties of the Walk-12G in people with multiple sclerosis (MS) and Parkinson’s disease (PD). The Walk-12G was translated into Swedish and evaluated qualitatively among 25 people with and without various neurological and other conditions. Postal survey (MS, n = 199; PD, n = 189) and clinical (PD, n = 36) data were used to test its psychometric properties. Respondents considered the Walk-12G relevant and easy to use. Mean completion time was 3.5 min. Data completeness was good (<5% missing item responses) and tests of scaling assumptions supported summing item scores to a total score (corrected item-total correlations >0.6). Coefficient alpha and test–retest reliabilities were >0.9, and standard errors of measurement were 2.3–2.8. Construct validity was supported by correlations in accordance with a priori expectations. Results are similar to those with previous Walk-12G versions, indicating that scale adaptation was successful. Data suggest that the Walk-12G meets rating scale criteria for clinical trials, making it a valuable complement to available gait tests. Further studies involving other samples and application of modern psychometric methods are warranted to examine the scale in more detail.

sted, utgiver, år, opplag, sider
2012. Vol. 259, nr 4, s. 729-738
Emneord [en]
Multiple sclerosis, Outcome assessment, Parkinson’s disease, Psychometrics, Walking
HSV kategori
Identifikatorer
URN: urn:nbn:se:hkr:diva-8545DOI: 10.1007/s00415-011-6254-zISI: 000302489400018PubMedID: 21956376OAI: oai:DiVA.org:hkr-8545DiVA, id: diva2:441409
Tilgjengelig fra: 2011-09-15 Laget: 2011-09-15 Sist oppdatert: 2017-12-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Westergren, AlbertHagell, Peter

Søk i DiVA

Av forfatter/redaktør
Westergren, AlbertHagell, Peter
Av organisasjonen
I samme tidsskrift
Journal of Neurology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 266 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf