hkr.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
High flow-rate sample loading in large volume whole water organic trace analysis using positive pressure and finely ground sand as a SPE-column in-line filter
Högskolan Kristianstad, Plattformen för molekylär analys. Högskolan Kristianstad, Fakulteten för naturvetenskap, Avdelningen för miljö- och biovetenskap. Högskolan Kristianstad, Fakulteten för naturvetenskap, Forskningsmiljön MoLab.
Högskolan Kristianstad, Plattformen för molekylär analys. Högskolan Kristianstad, Fakulteten för naturvetenskap, Avdelningen för miljö- och biovetenskap. Högskolan Kristianstad, Fakulteten för naturvetenskap, Forskningsmiljön MoLab.ORCID-id: 0000-0003-2283-2927
2019 (engelsk)Inngår i: Molecules, ISSN 1420-3049, E-ISSN 1420-3049, Vol. 24, nr 7Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

By using an innovative, positive pressure sample loading technique in combination with an in-line filter of finely ground sand the bottleneck of solid phase extraction (SPE) can be reduced. Recently published work by us has shown the proof of concept of the technique. In this work, emphasis is put on the SPE flow rate and method validation for 26 compounds of emerging environmental concern, mainly from the 1st and 2nd EU Watch List, with various physicochemical properties. The mean absolute recoveries in % and relative standard deviations (RSD) in % for the investigated compounds from spiked pure water samples at the three investigated flow rates of 10, 20, and 40 mL/min were 63.2% (3.2%), 66.9% (3.3%), and 69.0% (4.0%), respectively. All three flow rates produced highly repeatable results, and this allowed a flow rate increase of up to 40 mL/min for a 200 mg, 6 mL, reversed phase SPE cartridge without compromising the recoveries. This figure is more than four times the maximum flow rate recommended by manufacturers. It was indicated that some compounds, especially pronounced for the investigated macrolide molecules, might suffer when long contact times with the sample glass bottle occurs. A reduced contact time somewhat decreases this complication. A very good repeatability also held true for experiments on both spiked matrix-rich pond water (high and low concentrations) and recipient waters (river and wastewater) applying 40 mL/min. This work has shown that, for a large number of compounds of widely differing physicochemical properties, there is a generous flow rate window from 10 to 40 mL/min where sample loading can be conducted. A sample volume of 0.5 L, which at the recommended maximum flow rate speed of 10 mL/min, would previously take 50 min, can now be processed in 12 min using a flow rate of 40 mL/min. This saves 38 min per processed sample. This low-cost technology allows the sample to be transferred to the SPE-column, closer to the sample location and by the person taking the sample. This further means that only the sample cartridge would need to be sent to the laboratory, instead of the whole water sample, like today's procedure.

sted, utgiver, år, opplag, sider
2019. Vol. 24, nr 7
Emneord [en]
SPE, environmental analysis, flow rate, hormones, in-line filter, large volume, pesticides, pharmaceuticals, sand, trace analysis, whole water
HSV kategori
Identifikatorer
URN: urn:nbn:se:hkr:diva-19231DOI: 10.3390/molecules24071426ISI: 000464952900022PubMedID: 30978956OAI: oai:DiVA.org:hkr-19231DiVA, id: diva2:1305336
Tilgjengelig fra: 2019-04-16 Laget: 2019-04-16 Sist oppdatert: 2019-06-28bibliografisk kontrollert

Open Access i DiVA

fulltext(728 kB)23 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 728 kBChecksum SHA-512
9a93f3816a8b490702f98356271b0dafff17109e6c1fb93c5c9459c9b57cd6a07d792f38ca478d2333969213f2a607af31adb8b53debfb4dda37432f4e59da27
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Svahn, OlaBjörklund, Erland

Søk i DiVA

Av forfatter/redaktør
Svahn, OlaBjörklund, Erland
Av organisasjonen
I samme tidsskrift
Molecules

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 23 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 302 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf