hkr.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Triggningskriterier i triggningsmodul för trådlösa dataloggern DL141E
Högskolan Kristianstad, Fakulteten för naturvetenskap, Avdelningen för datavetenskap.
Högskolan Kristianstad, Fakulteten för naturvetenskap, Avdelningen för datavetenskap.
2018 (svensk)Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgaveAlternativ tittel
Triggering Criteria in Trigger Module for Wireless Data Logger DL141E (engelsk)
Abstract [sv]

Dataloggern DL141E möjliggör kontinuerlig loggnig av mätdata från sensorer på upp till 30k sampel/s, som vidare kan överföras till mobiltelefoner via trådlös kommunikation. Detta är dock för stora datamängder per tidsenhet för mobiltelefoner som är tekniskt begränsade. Därför önskas bara relevant mätdata för att reducerar denna onödiga datamängd. I denna studie föreslås ett tillvägagångssätt där enspecifik mindre samling av diskreta försampel loggas i tur och ordning. Varje samling signalbehandlas genom att ställas mot fördefinierade triggningskriterier för att trigga loggning av en stor uppsättning av sampel på bara intressanta signalavvikelser. Dessa triggningskriterier är en särskild nivåöverskridning och signalriktning i kombination med ett antal sampel i följd. Studien förser en granskning av hur signalberäkningsmetoden ”Lebesgue sampling” kan tillämpas med kriterierna för god träffsäkerhet och en skälig beräkningstid i mobiltelefoner. Detta beaktas med dataloggerns vanligaste signaltyper puls och ramp i en miljö där småbrus och transienter förekommer. Träffsäkerheten och beräkningsbördan beaktasför att bedöma Lebesgue metodens effektivitet och antal nödvändiga försampel per uppsättning. Implementeringen görs i Java Android plattform och integreras därefter i en digital triggningsmodul med Graphical User Interface (GUI).

Abstract [en]

With the data logger DL141E it’s possible to continuously log measurement data from sensors up to 30k samples per second, and then transferring them to a mobile phone with Bluetooth technology. But this is by far too much sample data in a small time for a mobile phone with technical limitations to receive. That’s why only relevant measurement data should be mass logged to reduce the unnecessary data amount. Int his study a new approach is proposed where a specific and smaller amount of discrete pre-samples are logged in sequence. Every set of pre-samples is processed by comparing them to the user pre-defined trigger criterias. Met criterias will trigger logging of a massive set of samples on basis of only interesting signal deviations. The following trigger criterias are used: a specific signal level to cross, a specific signal direction, and both of these in combination with an amount of consecutive samples. The study provides an examination on how the signal processing method ”Lebesgue sampling” can be applied with the above criterias to achieve a god accuracy with reasonable processing time on mobile phones. This is observed using sensors with the most common signal types ramp and pulse in an environment where small noises and transients occur. The accuracy and the processing load are taken into account when estimating the efficiency of Lebesgue method and when estimating how many pre-samples per set might be sufficient. The implementation is written in Java Android platform and then integrated into a digital triggering module with Graphical User Interface (GUI).

sted, utgiver, år, opplag, sider
2018. , s. 54
Emneord [en]
Data logger DL141E, signal processing, ramp, pulse, software triggering criterias, pre-samples, Lebesgue sampling, send on delta
Emneord [sv]
Dataloggern DL141E, signalbehandling, ramp, puls, mjukvarumässiga triggningskriterier, försampel, Lebesgue sampling, send on delta
HSV kategori
Identifikatorer
URN: urn:nbn:se:hkr:diva-18292OAI: oai:DiVA.org:hkr-18292DiVA, id: diva2:1225390
Eksternt samarbeid
Carl-Axel Olsson (BlueCenter Sweden AB)
Utdanningsprogram
Bachelor programme in Computer Science and Engineering
Veileder
Examiner
Tilgjengelig fra: 2018-06-29 Laget: 2018-06-26 Sist oppdatert: 2021-06-10bibliografisk kontrollert

Open Access i DiVA

fulltext(1903 kB)194 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1903 kBChecksum SHA-512
5de759a830002dd5bb115ed788fa9ab8bff88541af7b06ff985ed1d6cabea3d6d66dfd86f917ce2d784ff7c0890fca9a2eb98f30bcbcada9d82cf657f050cf5d
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 194 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 310 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf