hkr.sePublikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Development of a solid phase extraction method for the simultaneous determination of steroid hormones in H295R cell line using liquid chromatography–tandem mass spectrometry
Storbritannien.
Högskolan Kristianstad, Sektionen för lärande och miljö, Avdelningen för Naturvetenskap. Högskolan Kristianstad, Plattformen för molekylär analys.ORCID-id: 0000-0003-2283-2927
USA.
2013 (engelsk)Inngår i: Journal of chromatography. B, ISSN 1570-0232, E-ISSN 1873-376X, Vol. 935, nr September, 61-69 s.Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The H295R in vitro cell line produces the majority of the steroidogenesis, for which reason it is commonly used as a screening tool for endocrine disrupting chemicals. Simultaneous determination of the precursor cholesterol and key steroid hormones could give a broad insight into the mechanistic disruption of the steroidogenesis. Steroid hormones have primarily been extracted from H295R incubation medium by means of liquid-liquid extraction (LLE) and the obtained recoveries and matrix effects have typically not been stated or assessed. In the present study a solid-phase extraction (SPE) method was developed and validated for the simultaneous extraction of cholesterol and five key steroid hormones pregnenolone, 17-hydroxyprogesterone, testosterone, cortisol and aldosterone from H295R incubation medium, and finally detected by LC-MS/MS. Cholesterol was recovered at a level of 55.7%, while steroid hormone recoveries ranged from 98.2 to 109.4%. Matrix effects varied between -0.6% and 62.8%. Intra-day precision was deemed acceptable, but the inter-day precision for pregnenolone and aldosterone exceeded the precision limit of 15% RSD. Although LLE has been the most frequently used extraction method in H295R studies, however, our investigation has shown that SPE may relatively easily extract and recover steroid hormones, potentially replacing LLE.

sted, utgiver, år, opplag, sider
2013. Vol. 935, nr September, 61-69 s.
Emneord [en]
Solid Phase Extraction, LC-MS/MS, Cholesterol, Steroid hormones, H295R incubation medium, Steroidogenesis.
HSV kategori
Identifikatorer
URN: urn:nbn:se:hkr:diva-10816DOI: 10.1016/j.jchromb.2013.07.013ISI: 000324084200010PubMedID: 23948237OAI: oai:DiVA.org:hkr-10816DiVA: diva2:639152
Tilgjengelig fra: 2013-08-06 Laget: 2013-08-06 Sist oppdatert: 2017-04-20bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Björklund, Erland

Søk i DiVA

Av forfatter/redaktør
Björklund, Erland
Av organisasjonen
I samme tidsskrift
Journal of chromatography. B

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 163 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf